In the Update Driver window, choose Browse my computer for driver software. In the next window, click the Browse button and navigate to the location of the extracted folder e. Be sure you are in the CDM Setup folder. This is a repeat of the previous steps. Please follow the instructions below. Right-click on the Optima entry and choose Update Driver Software. In the next window, click the Browse button and navigate to the location of the extracted folder again and click OK and Next.

Disconnect the Optima cable from your computer's USB port and connect it again. Skip to main content. Toggle navigation. Not Connected in software It is normal behavior that as long as the Neurobit settings window is open, the software is not connected to the Optima. Check that you connected the Optima cable and turned it on. Check Neurobit Optima settings. Device Model e. If unable to change device, run Neurobit setup file again. Make sure at least channel A is enabled. Restart Optima Turn off Optima.

Turn on again. Press panic button. Extract and right-click and run as administrator. Device Descriptor Request Failed This error usually results from hardware cable or device problem. If it is not green, be sure your device is turned on. The Pocket Neurobics driver must be installed before connecting to the software. If you have not already done so, download the PN Wiz Driver. This would have been installed running the wiz amplifier setup.

Save and then right-click to run as administrator. Then continue with connecting to the software. Then click the USB symbol. Find which port to use. Generally these do not need to be changed.

Clicking any of them will open a sub-menu from which to choose the type of training you want to do. The protocols are categorized into the following types:. More information on protocols is found in the Design Options section. Status checker top left indicates whether the program is turned on or off. When it is green, the program is receiving a signal from the device. When red, the program is stopped.

Click to select an action. It can be used anytime you make a change that is not automatically detected by the system.

It can be useful if you have a frozen screen and the refresh does not solve the issue. It should be used also after making changes in the device setup if the device does not connect green Source color. Click to open. The update checker checks for new updates and prompts the user to update now. You can set automatic updates as often as you prefer. A green light means the system is receiving data from the device.

This also opens the Device menu. Here you can set up your devices and select device settings. This is done from the Main Screen. Protocol loader allows you to load a pre-saved protocol for a specific client. See Saving protocols and Loading saved protocols. Designs menu allows you to select a protocol for training. This appears the same as on the Main menu of the program. Protocol saver allows you to save a pre-configured protocol for a specific client and even create all protocols for the entire Whole-Brain Training Plan to send as a folder for a client.

Signal tester shows the raw EEG and histogram to check for signal quality. Click and drag corner to resize window. Feedback manager opens window to customize feedback settings. Sound configuration opens settings for changing feedback sounds. Select MIDI sounds or click sound. Midi sound control turns MIDI feedback tones off or on. Click to turn off or back on. Select from 1 channel, 2 channels summed and 4 channels summed.

Signals are added together before going forward to filters leaving a single target for all sites in each training band. For your convenience, a button is available for pre-set protocols Centering 2-channel summed , Trauma Release 1C and Windowed squash 4C under Design setup. Pause, Play and Stop buttons are at the top left of the designs for starting and stopping a session.

Notice that the active available button- Play — is blue before the session is started. While a session is playing, the active buttons — Pause or Stop — are blue.

Restart must be pressed before making any further selections, including opening a new design. The Signal Tester allows the trainer to check for signal quality before starting the session. This window has raw EEG signal and spectral displays just as in each design, though the signal can be assessed more easily due to the larger size of the instruments. The signal tester shows the actual signal that is sent by the amplifier.

Open the Signal Tester window by clicking the wave icon. The Signal Tester window can be sized larger by clicking and dragging the corner of the window. This can be opened at any time before or while the session is playing. This displays the raw EEG. Signal quality can be checked and the EEG can be visualized and assessed. This spectral display shows the amplitudes for all frequencies. The frequency bands are divided by color.

In the order that they appear, they are as follows:. MIDI music is set as the default feedback. Other available feedback options are shown depending on the design and which modules are installed. The feedback manager is a control panel from which settings are selected for the feedback that is chosen. MIDI sound configuration is for advanced users only. MIDI sounds can be muted if desired by clicking the blue speaker icon.

Click to mute and unmute. Thresholds are target levels that are set for training. If the box is ticked, the threshold will become visible and active.

Feedback is usually given when the target is met training signal is either above or below the threshold bar. Most designs set thresholds automatically or switch to manual after baseline gathering period e. The top number indicates the running average of the signal value e. Training can be done with just the default MIDI sound tones and click sound or you can select enhanced feedback from our available options.

Games feedback is an add-on option for feedback. The games panel has a selection of 8 games plus the option to load your own flash game that is compatible with Brain-Trainer, such as other BioPLAY games, that are not included with Brain-Trainer software. Required inputs for such games are:. Most trainers will use only the Brain-Trainer interface and designs.

For advanced trainers with knowledge of programming designs themselves, BioEra Pro can be run on its own. Find the file bioera. You may see a window asking for a password. Click cancel. This only refers to the specific design. It is possible to create a new design or load a design from the computer. Please see our troubleshooting page for Brain-Trainer for BioEra software. This manual is under construction. By using this site, you are giving your consent to set cookies.

Privacy Policy. Email or Username. Remember Me. For access to Brain-Trainer U and brain-trainer. To access, our client report tool and trainer support resources, visit our Provider site.

Cart Login. Skip to content Toggle navigation. The Optima should be powered on. The device should be displayed in the status bar. Skip to main content. Toggle navigation.

Open BioExplorer. BioExplorer Program Opened No design has been loaded yet. Connect Optima device to computer and Power on the device Connect the amplifier power cable to the amplifier and connect to your computer's USB port. Trouble with driver installation? Check with USB View tool. Select BioExplorer from the menu bar The menu bar is the area with a horizontal list of options from which to select to use BioExplorer.

Select Device from the BioExplorer menu. Open Optima Config Window.